CCPortal
DOI10.1016/j.applthermaleng.2018.11.117
Theoretical study of cryogen spray cooling with R134a, R404A and R1234yf: Comparison and clinical potential application
Chen, Bin; Tian, Jiameng; Wang, Rui; Zhou, Zhifu
发表日期2019
ISSN1359-4311
卷号148页码:1058-1067
英文摘要

In laser dermatology, cryogen spray cooling has been used to protect the epidermis from unwanted thermal damage. In this work, spray characteristics and surface heat transfer dynamics were simulated by two-way coupling hybrid vortex method to evaluate the surface cooling capacity of R134a, R404A and R1234yf in terms of cooling density and effective heat flux. Simulation results reveal that R404A has the largest cooling capacity and smallest dispersion. R1234yf has similar spray characteristics but smaller dispersion compared with R134a. The maximum effective heat flux for R134a, R404A and R1234yf was determined as 262.1, 407.5 and 225.8 kW/m(2) at the spray distances of 25.6, 30.8 and 25.1 mm, respectively. Substituting the environment friendly R1234yf for R134a can remarkably reduce global warming potential by over 1430 times and increase cooling density but insufficient cooling capacity. The effective heat flux of R1234yf can be enhanced by 18.8% by reducing the nozzle diameter and decreasing the back pressure (D = 0.4 mm, P-b = 0.01 MPa). This result is comparable with that of R134a under 1 atm and provides a theoretical basis for R1234yf potential application in clinics.


WOS研究方向Thermodynamics ; Energy & Fuels ; Engineering ; Mechanics
来源期刊APPLIED THERMAL ENGINEERING
文献类型期刊论文
条目标识符http://gcip.llas.ac.cn/handle/2XKMVOVA/93279
作者单位Xi An Jiao Tong Univ, State Key Lab Multiphase Flow Power Engn, Xian 710049, Shaanxi, Peoples R China
推荐引用方式
GB/T 7714
Chen, Bin,Tian, Jiameng,Wang, Rui,et al. Theoretical study of cryogen spray cooling with R134a, R404A and R1234yf: Comparison and clinical potential application[J],2019,148:1058-1067.
APA Chen, Bin,Tian, Jiameng,Wang, Rui,&Zhou, Zhifu.(2019).Theoretical study of cryogen spray cooling with R134a, R404A and R1234yf: Comparison and clinical potential application.APPLIED THERMAL ENGINEERING,148,1058-1067.
MLA Chen, Bin,et al."Theoretical study of cryogen spray cooling with R134a, R404A and R1234yf: Comparison and clinical potential application".APPLIED THERMAL ENGINEERING 148(2019):1058-1067.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Chen, Bin]的文章
[Tian, Jiameng]的文章
[Wang, Rui]的文章
百度学术
百度学术中相似的文章
[Chen, Bin]的文章
[Tian, Jiameng]的文章
[Wang, Rui]的文章
必应学术
必应学术中相似的文章
[Chen, Bin]的文章
[Tian, Jiameng]的文章
[Wang, Rui]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。