Climate Change Data Portal
DOI | 10.1016/j.scitotenv.2018.08.150 |
CO2 and N2O from water resource recovery facilities: Evaluation of emissions from biological treatment, settling, disinfection, and receiving water body | |
Caniani, D.1; Caivano, M.1; Pascale, R.1; Bianco, G.2; Mancini, I. M.1; Masi, S.1; Mazzone, G.1; Firouzian, M.3; Rosso, D.3,4 | |
发表日期 | 2019 |
ISSN | 0048-9697 |
EISSN | 1879-1026 |
卷号 | 648页码:1130-1140 |
英文摘要 | Water resource recovery facilities (WRRFs) contribute to climate change and air pollution, as they are anthropogenic potential sources of direct and indirect emission of greenhouse gases (GHGs). Studies concerning the monitoring and accounting for GHG emissions from WRRFs are of increasing interest. In this study, the floating hood technique for gas collection was coupled with the off-gas method to monitor and apportion nitrous oxide (N2O) and carbon dioxide (CO2) emissions from both aerated and non-aerated tanks in a municipal water resource recovery facility, in order to investigate its carbon footprint (CFP). To our knowledge, this is the first time that the chamber technique was applied to evaluate gas fluxes from the settler, where an emission factor (EF) of 4.71 *10(-5) kg(CO2,eq) kg(bCOD)(-1) was found. Interesting results were found in the disinfection unit, which was the major contributor to direct N2O emissions (with a specific emission factor of 0.008 kg(CO2,eq) kg(bCOD)(-1)), due to the chemical interaction between hydroxylamine and the disinfectant agent (hypochlorite). The specific emission factor of the biological aerated tank was 0.00112 kg(CO2,eq) kg(bCOD)(-1). The average direct CO2 emission was equal to 0.068 kg(CO2) kg(bCOD)(-1) from the activated sludge tank and to 0.00017 kg(CO2) kg(bCOD)(-1) from the secondary clarifier. Therefore, taking into account the contribution of both direct N2O and CO2 emissions, values of 0.069 kg(CO2),(eq) kg(bCOD)(-1), 0.008 kg(CO2),(eq) kg(bCOD)(-1) and 0.00022 kg(CO2,eq) kg(bCOD)(-1), were found for the net CFP of the aerated compartment, the disinfection unit and the clarifier, respectively. The plant energy Footprint (eFP) was also evaluated, confirming that the aeration systemis the major contributor to energy consumption, as well as to indirect CO2 emission, with a specific eFP of 1.49 kWh kg(bCOD)(-1). (C) 2018 Elsevier B.V. All rights reserved. |
WOS研究方向 | Environmental Sciences & Ecology |
来源期刊 | SCIENCE OF THE TOTAL ENVIRONMENT
![]() |
文献类型 | 期刊论文 |
条目标识符 | http://gcip.llas.ac.cn/handle/2XKMVOVA/92122 |
作者单位 | 1.Univ Basilicata, Engn Sch, Viale Ateneo Lucano 10, I-85100 Potenza, Italy; 2.Univ Basilicata, Dipartimento Sci, Viale Ateneo Lucano 10, I-85100 Potenza, Italy; 3.Univ Calif Irvine, Civil & Environm Engn Dept, Irvine, CA 92697 USA; 4.Univ Calif Irvine, Water Energy Nexus Ctr, Irvine, CA 92697 USA |
推荐引用方式 GB/T 7714 | Caniani, D.,Caivano, M.,Pascale, R.,et al. CO2 and N2O from water resource recovery facilities: Evaluation of emissions from biological treatment, settling, disinfection, and receiving water body[J],2019,648:1130-1140. |
APA | Caniani, D..,Caivano, M..,Pascale, R..,Bianco, G..,Mancini, I. M..,...&Rosso, D..(2019).CO2 and N2O from water resource recovery facilities: Evaluation of emissions from biological treatment, settling, disinfection, and receiving water body.SCIENCE OF THE TOTAL ENVIRONMENT,648,1130-1140. |
MLA | Caniani, D.,et al."CO2 and N2O from water resource recovery facilities: Evaluation of emissions from biological treatment, settling, disinfection, and receiving water body".SCIENCE OF THE TOTAL ENVIRONMENT 648(2019):1130-1140. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。