英文摘要 | In recognition of the impact of the refrigeration sector on climate change, global commitments are achieved to replace hydrofluorocarbon substances with more planet-friendly alternatives. In this regard, countries with high ambient temperatures (HAT) face additional problems in identifying suitable alternatives due to the impact of such temperatures on energy performance in vapor compression systems. This paper presents an experimental analysis using R134a and two lower global warming potential (GWP) mixtures in a small capacity vapor compression refrigeration system for HAT environments. The range of evaporating and condensing conditions was selected to simulate a refrigeration system working at HAT conditions. The experimental operating results show that although R450A values are acceptable, R513A shows better adaptation to the refrigeration system in terms of pressure ratio, discharge temperature, and mass flow rate. Then, attending to experimental energetic results, R450A energy performance (quantified by COP) and cooling capacity are lower than R513A and R134a. TEWI analysis of a small refrigeration unit shows CO2 equivalent emission saving when using R450A in the different condensation conditions. However, taking into account the variation of cooling capacity, R513A system results in the lowest TEWI when normalizing per unit of delivered cooling capacity. (C) 2018 Elsevier Ltd. All rights reserved. |
WOS研究方向 | Thermodynamics ; Energy & Fuels |
来源期刊 | ENERGY
![]() |
文献类型 | 期刊论文 |
条目标识符 | http://gcip.llas.ac.cn/handle/2XKMVOVA/90480 |
作者单位 | 1.Royal Inst Technol, Div Appl Thermodynam & Refrigerat, Dept Energy Technol, Brinellvagen 68, S-10044 Stockholm, Sweden; 2.Univ Jaume 1, Dept Mech Engn & Construct, ISTENER Res Grp, Campus Riu Sec S-N, E-12071 Castellon De La Plana, Spain; 3.Tech Univ Cartagena, Engn & Appl Technol Dept, Univ Ctr Def, Spanish Air Force Acad,Minist Def, C Coronel Lopez Pena S-N, Murcia 30720, Spain |
推荐引用方式 GB/T 7714 | Makhnatch, Pavel,Mota-Babiloni, Adrian,Lopez-Belchi, Alejandro,et al. R450A and R513A as lower GWP mixtures for high ambient temperature countries: Experimental comparison with R134a[J],2019,166:223-235. |
APA | Makhnatch, Pavel,Mota-Babiloni, Adrian,Lopez-Belchi, Alejandro,&Khodabandeh, Rahmatollah.(2019).R450A and R513A as lower GWP mixtures for high ambient temperature countries: Experimental comparison with R134a.ENERGY,166,223-235. |
MLA | Makhnatch, Pavel,et al."R450A and R513A as lower GWP mixtures for high ambient temperature countries: Experimental comparison with R134a".ENERGY 166(2019):223-235. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。