Climate Change Data Portal
DOI | 10.1016/j.atmosenv.2013.04.064 |
Observations of interference between portable particle counters and NOx monitors | |
Bereznicki, Sarah D.; Kamal, Ali | |
发表日期 | 2013-08-01 |
ISSN | 1352-2310 |
卷号 | 75页码:303-307 |
英文摘要 | Studies in environmental exposure science have developed a preference for smaller devices that can be easily co-located without need for gas standards, such as those instruments utilized in the Near-road Exposures and Effects from Urban Air Pollutants Study (NEXUS). One observation from NEXUS was the potential for instrument interference from alcohol-based particle counters on photometric-based nitrogen oxide (NOx ) monitors. This article reports the findings from laboratory tests replicating enclosedshelter monitoring configurations and operation cycles for a common photometric-based NOx monitor and a widely used alcohol-based particle counter. These tests monitored the NOx response while the particle counter sampling interval and ambient airflow rate were varied to (1) confirm that proximity between the instruments induced interferences, (2) identify any dependencies in NOx monitor recovery on ambient airflow, and (3) determine the time needed for the NOx monitor to recover to preinterference levels under different atmospheric conditions. During particle counter operations, NOx concentrations responded instantaneously with a several-fold jump above the measurement baseline. When the particle counter was operated for more than 10 min, this interference period also showed a marked decline in the NOx baseline. The overall recovery time of the NOx monitor depended less on the time of particle counter operation, and more on the speed of ambient airflow. If photometric-based NOx monitors need to be operated alongside alcohol-based particle counters, mechanisms must be employed to exhaust alcohol-based vapors from enclosed monitoring environments. Given the strong evidence for interference, however, it is recommended these devices not be operated within close proximity to one another. Published by Elsevier Ltd. |
英文关键词 | Interference;Particle counter;NOx monitor |
语种 | 英语 |
WOS记录号 | WOS:000321473100036 |
来源期刊 | ATMOSPHERIC ENVIRONMENT
![]() |
来源机构 | 美国环保署 |
文献类型 | 期刊论文 |
条目标识符 | http://gcip.llas.ac.cn/handle/2XKMVOVA/62522 |
作者单位 | US EPA, Res Triangle Pk, NC 27711 USA |
推荐引用方式 GB/T 7714 | Bereznicki, Sarah D.,Kamal, Ali. Observations of interference between portable particle counters and NOx monitors[J]. 美国环保署,2013,75:303-307. |
APA | Bereznicki, Sarah D.,&Kamal, Ali.(2013).Observations of interference between portable particle counters and NOx monitors.ATMOSPHERIC ENVIRONMENT,75,303-307. |
MLA | Bereznicki, Sarah D.,et al."Observations of interference between portable particle counters and NOx monitors".ATMOSPHERIC ENVIRONMENT 75(2013):303-307. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。