Climate Change Data Portal
DOI | 10.1002/rcm.6426 |
Direct gas injection method: A simple modification to an elemental analyzer/isotope ratio mass spectrometer for stable isotope analysis of N and C from N2O and CO2 gases in nanomolar concentrations | |
Machavaram, Madhav V.1; Beaulieu, Jake J.2; Mills, Marc A.2 | |
发表日期 | 2013-01-15 |
ISSN | 0951-4198 |
卷号 | 27期号:1页码:97-102 |
英文摘要 | RATIONALE Stable isotope analyses of trace amounts of nitrous oxide gas require special instrumentation and laborious sample preparation methods that have hindered many laboratories from measuring this potent greenhouse gas. A simple modification to an Elemental Analyzer (EA) coupled to an Isotope Ratio Mass Spectrometry (IRMS) setup that allows users to measure the N and C isotopic ratios of nitrous oxide (N2O) and carbon dioxide (CO2) by injecting the gases directly into the EA is described. METHODS The standard EA was fitted with a gas injection port and a home-made packed column filled with Hayesep Q polymer. A gas mixture of 3.1% N2O in helium (He) was injected directly into the EA. This method allowed large volumes of sample to be injected without saturating the column. RESULTS The use of the home-made column resulted in better resolution of sample peaks and allowed smaller concentrations of the analyte to be injected. This study showed that this method produced accurate and reproducible stable isotope measurements with sample injection volumes ranging from 100 to 5000 mu L, containing between 20 and 1000?nmol of analyte. CONCLUSIONS This simple, inexpensive method can be useful for the laboratories that do not have access to more advanced and expensive interfaces to analyze nanomolar quantities of N2O and CO2 from microbiological and ecological studies and offers a simple alternative for in-house measurements of these trace gases. Copyright (c) 2012 John Wiley & Sons, Ltd. |
语种 | 英语 |
WOS记录号 | WOS:000312536700009 |
来源期刊 | RAPID COMMUNICATIONS IN MASS SPECTROMETRY
![]() |
来源机构 | 美国环保署 |
文献类型 | 期刊论文 |
条目标识符 | http://gcip.llas.ac.cn/handle/2XKMVOVA/62331 |
作者单位 | 1.US EPA, Pegasus Tech Serv Inc, Cincinnati, OH 45268 USA; 2.US EPA, Natl Risk Management Res Lab, Cincinnati, OH 45268 USA |
推荐引用方式 GB/T 7714 | Machavaram, Madhav V.,Beaulieu, Jake J.,Mills, Marc A.. Direct gas injection method: A simple modification to an elemental analyzer/isotope ratio mass spectrometer for stable isotope analysis of N and C from N2O and CO2 gases in nanomolar concentrations[J]. 美国环保署,2013,27(1):97-102. |
APA | Machavaram, Madhav V.,Beaulieu, Jake J.,&Mills, Marc A..(2013).Direct gas injection method: A simple modification to an elemental analyzer/isotope ratio mass spectrometer for stable isotope analysis of N and C from N2O and CO2 gases in nanomolar concentrations.RAPID COMMUNICATIONS IN MASS SPECTROMETRY,27(1),97-102. |
MLA | Machavaram, Madhav V.,et al."Direct gas injection method: A simple modification to an elemental analyzer/isotope ratio mass spectrometer for stable isotope analysis of N and C from N2O and CO2 gases in nanomolar concentrations".RAPID COMMUNICATIONS IN MASS SPECTROMETRY 27.1(2013):97-102. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。