CCPortal
DOI10.1039/c4em00560k
Passive sampling for volatile organic compounds in indoor air-controlled laboratory comparison of four sampler types
McAlary, Todd1,3; Groenevelt, Hester1; Disher, Stephen2; Arnold, Jason2; Seethapathy, Suresh3; Sacco, Paolo4; Crump, Derrick5; Schumacher, Brian6; Hayes, Heidi2; Johnson, Paul7; Gorecki, Tadeusz3
发表日期2015
ISSN2050-7887
卷号17期号:5页码:896-905
英文摘要

This article describes laboratory testing of four passive diffusive samplers for assessing indoor air concentrations of volatile organic compounds (VOCs), including SKC Ultra II, Radiello (R), Waterloo Membrane Sampler (WMS) and Automated Thermal Desorption (ATD) tubes with two different sorbents (Tenax TA and Carbopack B). The testing included 10 VOCs (including chlorinated ethenes, ethanes, and methanes, aromatic and aliphatic hydrocarbons), spanning a range of properties and including some compounds expected to pose challenges (naphthalene, methyl ethyl ketone). Tests were conducted at different temperatures (17 to 30 degrees C), relative humidities (30 to 90% RH), face velocities (0.014 to 0.41 ms(-1)), concentrations (1 to 100 parts per billion by volume [ppb(v)]) and sampling durations (1 to 7 days). The results show that all of the passive samplers provided data that met the success criteria (relative percent difference [RPD] <= 45% of active sample concentrations and coefficient of variation [COV] <= 30%) in the majority of cases, but some compounds were problematic for some samplers. The passive sampler uptake rates depend to varying degrees on the sampler, sorbent, target compounds and environmental conditions, so field calibration is advantageous for the highest levels of data quality.


语种英语
WOS记录号WOS:000354412100001
来源期刊ENVIRONMENTAL SCIENCE-PROCESSES & IMPACTS
来源机构美国环保署
文献类型期刊论文
条目标识符http://gcip.llas.ac.cn/handle/2XKMVOVA/61194
作者单位1.Geosyntec Consultants Inc, Guelph, ON N1G 5G3, Canada;
2.Eurofins Air Tox Inc, Air Tox Ltd, Folsom, CA USA;
3.Univ Waterloo, Waterloo, ON N2L 3G1, Canada;
4.Fdn Salvatore Maugeri, Padua, Italy;
5.Cranfield Univ, Cranfield MK43 0AL, Beds, England;
6.US EPA, Las Vegas, NV 89193 USA;
7.Arizona State Univ, Tempe, AZ USA
推荐引用方式
GB/T 7714
McAlary, Todd,Groenevelt, Hester,Disher, Stephen,et al. Passive sampling for volatile organic compounds in indoor air-controlled laboratory comparison of four sampler types[J]. 美国环保署,2015,17(5):896-905.
APA McAlary, Todd.,Groenevelt, Hester.,Disher, Stephen.,Arnold, Jason.,Seethapathy, Suresh.,...&Gorecki, Tadeusz.(2015).Passive sampling for volatile organic compounds in indoor air-controlled laboratory comparison of four sampler types.ENVIRONMENTAL SCIENCE-PROCESSES & IMPACTS,17(5),896-905.
MLA McAlary, Todd,et al."Passive sampling for volatile organic compounds in indoor air-controlled laboratory comparison of four sampler types".ENVIRONMENTAL SCIENCE-PROCESSES & IMPACTS 17.5(2015):896-905.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[McAlary, Todd]的文章
[Groenevelt, Hester]的文章
[Disher, Stephen]的文章
百度学术
百度学术中相似的文章
[McAlary, Todd]的文章
[Groenevelt, Hester]的文章
[Disher, Stephen]的文章
必应学术
必应学术中相似的文章
[McAlary, Todd]的文章
[Groenevelt, Hester]的文章
[Disher, Stephen]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。