Quantification of Microcystin-LR in Human Urine by Immunocapture Liquid Chromatography Tandem Mass Spectrometry | |
Wharton, Rebekah E.1; Ojeda-Torres, Geovannie2,6; Cunningham, Brady2; Feyereisen, Melanie C.1; Hill, Kasey L.1,7; Abbott, Nicole L.3,8; Seymour, Craig3; Hill, Donna4; Lang, Johnsie5; Hamelin, Elizabeth, I1; Johnson, Rudolph C.1 | |
发表日期 | 2018-09-01 |
ISSN | 0893-228X |
卷号 | 31期号:9页码:898-903 |
英文摘要 | Microcystins are toxins produced by many cyanobacteria species, which are often released into waterways during blue-green algal blooms in freshwater and marine habitats. The consumption of microcystin-contaminated water is a public health concern as these toxins are recognized tumor promoters and are hepatotoxic to humans and animals. A method to confirm human exposures to microcystins is needed; therefore, our laboratory has developed an immunocapture liquid chromatography tandem mass spectrometry (LC-MS/MS) method targeting the conserved adda portion of microcystins for the quantitation of a prevalent and highly toxic congener of microcystin, microcystin-LR (MC-LR). An acute exposure method was initially evaluated for accuracy and precision by analyzing calibrators and quality control (QC) samples ranging from 0.500 to 75.0 ng/mL in urine. All calibrators and QC samples characterized were within 15% of theoretical concentrations. An analysis of acutely exposed mouse urine samples using this method identified MC-LR levels from 10.7 to 33.9 ng/mL. Since human exposures are anticipated to result from low-dose or chronic exposures, a high-sensitivity method was validated with 20 calibration curves and QC samples ranging from 0.0100 to 7.50 ng/mL. Relative standard deviations (RSDs) and inaccuracies of these samples were within 15%, meeting United States Food and Drug Administration (FDA) guidelines for analytical methods, and the limit of detection was 0.00455 ng/mL. In conclusion, we have developed a method which can be used to address public health concerns by precisely and accurately measuring MC-LR in urine samples. |
语种 | 英语 |
WOS记录号 | WOS:000445165200013 |
来源期刊 | CHEMICAL RESEARCH IN TOXICOLOGY
![]() |
来源机构 | 美国环保署 |
文献类型 | 期刊论文 |
条目标识符 | http://gcip.llas.ac.cn/handle/2XKMVOVA/61081 |
作者单位 | 1.Ctr Dis Control & Prevent, Div Lab Sci, Natl Ctr Environm Hlth, 1600 Clifton Rd, Atlanta, GA 30333 USA; 2.Ctr Dis Control & Prevent, Oak Ridge Inst Sci & Educ, 1600 Clifton Rd, Atlanta, GA 30333 USA; 3.Ctr Dis Control & Prevent, Battelle Mem Inst, 1600 Clifton Rd, Atlanta, GA 30333 USA; 4.Environm Protect Agcy, Natl Hlth & Environm Effects Res, 109 TW Alexander Dr, Res Triangle Pk, NC 27709 USA; 5.Environm Protect Agcy, Oak Ridge Inst Sci & Educ, 109 TW Alexander Dr, Res Triangle Pk, NC 27709 USA; 6.Waters Corp, Milford, MA 01757 USA; 7.Ohio State Univ, Columbus, OH 43210 USA; 8.Nevada State Publ Hlth Lab, Reno, NV 89503 USA |
推荐引用方式 GB/T 7714 | Wharton, Rebekah E.,Ojeda-Torres, Geovannie,Cunningham, Brady,et al. Quantification of Microcystin-LR in Human Urine by Immunocapture Liquid Chromatography Tandem Mass Spectrometry[J]. 美国环保署,2018,31(9):898-903. |
APA | Wharton, Rebekah E..,Ojeda-Torres, Geovannie.,Cunningham, Brady.,Feyereisen, Melanie C..,Hill, Kasey L..,...&Johnson, Rudolph C..(2018).Quantification of Microcystin-LR in Human Urine by Immunocapture Liquid Chromatography Tandem Mass Spectrometry.CHEMICAL RESEARCH IN TOXICOLOGY,31(9),898-903. |
MLA | Wharton, Rebekah E.,et al."Quantification of Microcystin-LR in Human Urine by Immunocapture Liquid Chromatography Tandem Mass Spectrometry".CHEMICAL RESEARCH IN TOXICOLOGY 31.9(2018):898-903. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。