CCPortal
DOI10.1080/10962247.2016.1184724
South Philadelphia passive sampler and sensor study
Thoma, Eben D.1; Brantley, Halley L.1,2; Oliver, Karen D.3; Whitaker, Donald A.1; Mukerjee, Shaibal1; Mitchell, Bill1,4; Wu, Tai1; Squier, Bill; Escobar, Elsy5; Cousett, Tamira A.6; Gross-Davis, Carol Ann7; Schmidt, Howard7; Sosna, Dennis8; Weiss, Hallie8
发表日期2016
ISSN1096-2247
卷号66期号:10页码:959-970
英文摘要

From June 2013 to March 2015, in total 41 passive sampler deployments of 2 wk duration each were conducted at 17 sites in South Philadelphia, PA, with results for benzene discussed here. Complementary time-resolved measurements with lower cost prototype fenceline sensors and an open-path ultraviolet differential optical absorption spectrometer were also conducted. Minimum passive sampler benzene concentrations for each sampling period ranged from 0.08 ppbv to 0.65 ppbv, with a mean of 0.25 ppbv, and were negatively correlated with ambient temperature (-0.01 ppbv/degrees C, R-2 = 0.68). Co-deployed duplicate passive sampler pairs (N = 609) demonstrated good precision with an average and maximum percent difference of 1.5% and 34%, respectively. A group of passive samplers located within 50 m of a refinery fenceline had a study mean benzene concentration of 1.22 ppbv, whereas a group of samplers located in communities >1 km distant from facilities had a mean of 0.29 ppbv. The difference in the means of these groups was statistically significant at the 95% confidence level (p < 0.001). A decreasing gradient in benzene concentrations moving away from the facilities was observed, as was a significant period-to-period variation. The highest recorded 2-wk average benzene concentration for the fenceline group was 3.11 ppbv. During this period, time-resolved data from the prototype sensors and the open-path spectrometer detected a benzene signal from the west on one day in particular, with the highest 5-min path-averaged benzene concentration measured at 24 ppbv.


Implications: Using a variation of EPA's passive sampler refinery fenceline monitoring method, coupled with time-resolved measurements, a multiyear study in South Philadelphia informed benzene concentrations near facilities and in communities. The combination of measurement strategies can assist facilities in identification and mitigation of emissions from fugitive sources and improve information on air quality complex air sheds.


语种英语
WOS记录号WOS:000386846300003
来源期刊JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION
来源机构美国环保署
文献类型期刊论文
条目标识符http://gcip.llas.ac.cn/handle/2XKMVOVA/60017
作者单位1.US EPA, Off Res & Dev, Natl Risk Managment Res Lab, Durham, NC USA;
2.Oak Ridge Inst Sci & Engn, Durham, NC USA;
3.US EPA, Off Res & Dev, Natl Exposure Res Lab, Durham, NC USA;
4.US EPA, Off Enforcement & Compliance Assurance, Natl Environm Invest Ctr, Denver, CO USA;
5.Arcadis US Inc, Philadelphia, PA USA;
6.Jacobs Technol Inc, Durham, NC USA;
7.US EPA, Reg 3, Philadelphia, PA USA;
8.City Philadelphia, Dept Publ Hlth, Air Management Serv Lab, Philadelphia, PA USA
推荐引用方式
GB/T 7714
Thoma, Eben D.,Brantley, Halley L.,Oliver, Karen D.,et al. South Philadelphia passive sampler and sensor study[J]. 美国环保署,2016,66(10):959-970.
APA Thoma, Eben D..,Brantley, Halley L..,Oliver, Karen D..,Whitaker, Donald A..,Mukerjee, Shaibal.,...&Weiss, Hallie.(2016).South Philadelphia passive sampler and sensor study.JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION,66(10),959-970.
MLA Thoma, Eben D.,et al."South Philadelphia passive sampler and sensor study".JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION 66.10(2016):959-970.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Thoma, Eben D.]的文章
[Brantley, Halley L.]的文章
[Oliver, Karen D.]的文章
百度学术
百度学术中相似的文章
[Thoma, Eben D.]的文章
[Brantley, Halley L.]的文章
[Oliver, Karen D.]的文章
必应学术
必应学术中相似的文章
[Thoma, Eben D.]的文章
[Brantley, Halley L.]的文章
[Oliver, Karen D.]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。