CCPortal
DOI10.1016/j.chemosphere.2013.06.020
Quality control for sampling of PCDD/PCDF emissions from open combustion sources
Gullett, Brian K.1; Tabor, Dennis1; Bertrand, Amelie2; Touati, Abderrahmane3
发表日期2013-09-01
ISSN0045-6535
卷号93期号:3页码:494-498
英文摘要

Both long duration (>6 h) and high temperature (up to 139 degrees C) sampling efforts were conducted using ambient air sampling methods to determine if either high volume throughput or higher than ambient air sampling temperatures resulted in loss of target polychlorinated dibenzodioxins/dibenzofurans (PCDDs/PCDFs) from a polyurethane foam (PUF) sorbent. Emissions from open burning of simulated military forward operating base waste were sampled using EPA Method TO-9A for 185 min duration using a filter/PUF/PUF in series combination. After a 54 m(3) sample was collected, the sampler was removed from the combustion source and the second PUF was replaced with a fresh, clean PUF. An additional 6 h of ambient air sampling (171 m(3)) was conducted and the second PUF was analyzed to determine if the PCDD/PCDF transferred from the filter and the first PUF. Less than 4.4% of the initial PCDD/PCDF was lost to the second PUF. To assess the potential for blow off of PCDD/PCDF analytes during open air sampling, the mobility of spiked mono- to hepta-PCDD/PCDF standards across a PUF sorbent was evaluated from ambient air temperatures to 145 degrees C with total volumes between 600 L and 2400 L. Lower molecular weight compounds and higher flow amounts increased release of the spiked standards consistent with vapor pressure values. At 600 L total sampled volume, the release temperature for 1% of the tetra-CDD (the lowest chlorinated homologue with a toxic compound) was 87 degrees C; increasing the volume fourfold reduced this temperature to 73 degrees C. Published by Elsevier Ltd.


英文关键词PCDD/PCDF;Sampling;Quality control;Open burning;Polyurethane foam;Blow off
语种英语
WOS记录号WOS:000324456700006
来源期刊CHEMOSPHERE
来源机构美国环保署
文献类型期刊论文
条目标识符http://gcip.llas.ac.cn/handle/2XKMVOVA/59880
作者单位1.US EPA, Off Res & Dev E343 04, Res Triangle Pk, NC 27711 USA;
2.Univ Orleans, Fac Sci, F-45067 Orleans, France;
3.ARCADIS US Inc, Durham, NC 27713 USA
推荐引用方式
GB/T 7714
Gullett, Brian K.,Tabor, Dennis,Bertrand, Amelie,et al. Quality control for sampling of PCDD/PCDF emissions from open combustion sources[J]. 美国环保署,2013,93(3):494-498.
APA Gullett, Brian K.,Tabor, Dennis,Bertrand, Amelie,&Touati, Abderrahmane.(2013).Quality control for sampling of PCDD/PCDF emissions from open combustion sources.CHEMOSPHERE,93(3),494-498.
MLA Gullett, Brian K.,et al."Quality control for sampling of PCDD/PCDF emissions from open combustion sources".CHEMOSPHERE 93.3(2013):494-498.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Gullett, Brian K.]的文章
[Tabor, Dennis]的文章
[Bertrand, Amelie]的文章
百度学术
百度学术中相似的文章
[Gullett, Brian K.]的文章
[Tabor, Dennis]的文章
[Bertrand, Amelie]的文章
必应学术
必应学术中相似的文章
[Gullett, Brian K.]的文章
[Tabor, Dennis]的文章
[Bertrand, Amelie]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。