Climate Change Data Portal
DOI | 10.1016/j.snb.2013.08.058 |
Amperometric carbon fiber nitrite microsensor for in situ biofilm monitoring | |
Lee, Woo Hyoung1; Wahman, David G.2; Pressman, Jonathan G.2 | |
发表日期 | 2013-11-01 |
ISSN | 0925-4005 |
卷号 | 188页码:1263-1269 |
英文摘要 | A highly selective needle type solid state amperometric nitrite microsensor based on direct nitrite oxidation on carbon fiber was developed using a simplified fabrication method. The microsensor's tip diameter was approximately 7 mu m (14 mu m spatial resolution). At an applied potential of +1.2 V vs. Ag/AgCl, the microsensor exhibited a linear nitrite response from 0 to 25 mg N L-1, a 0.02 mg N L-1(1.3 mu M) limit of detection, and a fast response (<5 s). There was minimal interference with less than 3% of electrode response changes from major chemicals of interest in drinking water and wastewater systems [oxygen, ammonium, monochloramine, nitrate, sodium bicarbonate (alkalinity), chloride, sulfate, and acetate]. Hydrogen ion (pH) affected nitrite measurement by shifting the baseline response, translating into an approximate change of 0.24 mg N L-1 nitrite per 1 pH unit change. Depending on the conditions (e. g., pH, alkalinity, nitrite concentration), pH may need to be taken into account during nitrite measurement. The developed carbon fiber nitrite microsensor successfully measured nitrite in a nitrifying biofilm and is applicable for in situ analysis in other micro-environments (e. g., microbial mats and sediments). Published by Elsevier B.V. |
英文关键词 | Biofilm;Carbon fiber;In situ monitoring;Microsensor;Nitrification;Nitrite |
语种 | 英语 |
WOS记录号 | WOS:000326345600170 |
来源期刊 | SENSORS AND ACTUATORS B-CHEMICAL
![]() |
来源机构 | 美国环保署 |
文献类型 | 期刊论文 |
条目标识符 | http://gcip.llas.ac.cn/handle/2XKMVOVA/58501 |
作者单位 | 1.Univ Cent Florida, Dept Civil Environm & Construct Engn, Orlando, FL 32816 USA; 2.US EPA, Natl Risk Management Res Lab, Cincinnati, OH 45268 USA |
推荐引用方式 GB/T 7714 | Lee, Woo Hyoung,Wahman, David G.,Pressman, Jonathan G.. Amperometric carbon fiber nitrite microsensor for in situ biofilm monitoring[J]. 美国环保署,2013,188:1263-1269. |
APA | Lee, Woo Hyoung,Wahman, David G.,&Pressman, Jonathan G..(2013).Amperometric carbon fiber nitrite microsensor for in situ biofilm monitoring.SENSORS AND ACTUATORS B-CHEMICAL,188,1263-1269. |
MLA | Lee, Woo Hyoung,et al."Amperometric carbon fiber nitrite microsensor for in situ biofilm monitoring".SENSORS AND ACTUATORS B-CHEMICAL 188(2013):1263-1269. |