CCPortal
DOI10.1016/j.snb.2013.08.058
Amperometric carbon fiber nitrite microsensor for in situ biofilm monitoring
Lee, Woo Hyoung1; Wahman, David G.2; Pressman, Jonathan G.2
发表日期2013-11-01
ISSN0925-4005
卷号188页码:1263-1269
英文摘要

A highly selective needle type solid state amperometric nitrite microsensor based on direct nitrite oxidation on carbon fiber was developed using a simplified fabrication method. The microsensor's tip diameter was approximately 7 mu m (14 mu m spatial resolution). At an applied potential of +1.2 V vs. Ag/AgCl, the microsensor exhibited a linear nitrite response from 0 to 25 mg N L-1, a 0.02 mg N L-1(1.3 mu M) limit of detection, and a fast response (<5 s). There was minimal interference with less than 3% of electrode response changes from major chemicals of interest in drinking water and wastewater systems [oxygen, ammonium, monochloramine, nitrate, sodium bicarbonate (alkalinity), chloride, sulfate, and acetate]. Hydrogen ion (pH) affected nitrite measurement by shifting the baseline response, translating into an approximate change of 0.24 mg N L-1 nitrite per 1 pH unit change. Depending on the conditions (e. g., pH, alkalinity, nitrite concentration), pH may need to be taken into account during nitrite measurement. The developed carbon fiber nitrite microsensor successfully measured nitrite in a nitrifying biofilm and is applicable for in situ analysis in other micro-environments (e. g., microbial mats and sediments). Published by Elsevier B.V.


英文关键词Biofilm;Carbon fiber;In situ monitoring;Microsensor;Nitrification;Nitrite
语种英语
WOS记录号WOS:000326345600170
来源期刊SENSORS AND ACTUATORS B-CHEMICAL
来源机构美国环保署
文献类型期刊论文
条目标识符http://gcip.llas.ac.cn/handle/2XKMVOVA/58501
作者单位1.Univ Cent Florida, Dept Civil Environm & Construct Engn, Orlando, FL 32816 USA;
2.US EPA, Natl Risk Management Res Lab, Cincinnati, OH 45268 USA
推荐引用方式
GB/T 7714
Lee, Woo Hyoung,Wahman, David G.,Pressman, Jonathan G.. Amperometric carbon fiber nitrite microsensor for in situ biofilm monitoring[J]. 美国环保署,2013,188:1263-1269.
APA Lee, Woo Hyoung,Wahman, David G.,&Pressman, Jonathan G..(2013).Amperometric carbon fiber nitrite microsensor for in situ biofilm monitoring.SENSORS AND ACTUATORS B-CHEMICAL,188,1263-1269.
MLA Lee, Woo Hyoung,et al."Amperometric carbon fiber nitrite microsensor for in situ biofilm monitoring".SENSORS AND ACTUATORS B-CHEMICAL 188(2013):1263-1269.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Lee, Woo Hyoung]的文章
[Wahman, David G.]的文章
[Pressman, Jonathan G.]的文章
百度学术
百度学术中相似的文章
[Lee, Woo Hyoung]的文章
[Wahman, David G.]的文章
[Pressman, Jonathan G.]的文章
必应学术
必应学术中相似的文章
[Lee, Woo Hyoung]的文章
[Wahman, David G.]的文章
[Pressman, Jonathan G.]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。