Monochloramine-sensitive amperometric microelectrode: optimization of gold, platinum, and carbon fiber sensing materials for removal of dissolved oxygen interference
Lee, Woo Hyoung1; Wahman, David. G.2; Pressman, Jonathan. G.2
发表日期2015-09-01
ISSN0947-7047
卷号21期号:9页码:2663-2674
英文摘要

Monochloramine electrochemical determination in an aqueous system using newly fabricated gold and platinum microelectrodes was investigated to optimize sensor operation and to eliminate dissolved oxygen (DO) interference during monochloramine measurements. Carbon fiber microelectrodes were also compared for reference purposes. Gold and platinum microelectrodes exhibited no oxygen interference during monochloramine measurement and provided a linear relationship when operated at +150 and +300 mV vs. Ag/AgCl over a wide concentration range (0-4.2 mg Cl-2/L), respectively. The carbon fiber microelectrode with 7-mu m tip diameter was not sufficiently sensitive to monochloramine concentrations for detailed study. The baseline signal of both gold and platinum microelectrodes (i.e., signal without monochloramine) was near zero. With the same geometric tip diameter (20-mu m tip diameter), gold microelectrodes resulted in better amperometric electrode response to monochloramine than platinum microelectrodes; gold microelectrodes had a higher sensitivity (52 +/- 0.7 vs. 18 +/- 0.07 pA/[mg Cl-2/L]) and lower detection limit (0.12 +/- 0.013 vs. 0.33 +/- 0.10 mg Cl-2/L), resulting in gold as the preferred microelectrode material. The developed gold microelectrode will allow accurate in situ monochloramine determination in biofilm while eliminating the confounding effects of oxygen interference.


英文关键词Microelectrode;Monochloramine;Oxygen interference;Gold;Platinum;Carbon fiber
语种英语
WOS记录号WOS:000360088500033
来源期刊IONICS
来源机构美国环保署
文献类型期刊论文
条目标识符http://gcip.llas.ac.cn/handle/2XKMVOVA/58459
作者单位1.Univ Cent Florida, Dept Civil Environm & Construct Engn, Orlando, FL 32816 USA;
2.US EPA, Natl Risk Management Res Lab, Cincinnati, OH 45268 USA
推荐引用方式
GB/T 7714
Lee, Woo Hyoung,Wahman, David. G.,Pressman, Jonathan. G.. Monochloramine-sensitive amperometric microelectrode: optimization of gold, platinum, and carbon fiber sensing materials for removal of dissolved oxygen interference[J]. 美国环保署,2015,21(9):2663-2674.
APA Lee, Woo Hyoung,Wahman, David. G.,&Pressman, Jonathan. G..(2015).Monochloramine-sensitive amperometric microelectrode: optimization of gold, platinum, and carbon fiber sensing materials for removal of dissolved oxygen interference.IONICS,21(9),2663-2674.
MLA Lee, Woo Hyoung,et al."Monochloramine-sensitive amperometric microelectrode: optimization of gold, platinum, and carbon fiber sensing materials for removal of dissolved oxygen interference".IONICS 21.9(2015):2663-2674.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Lee, Woo Hyoung]的文章
[Wahman, David. G.]的文章
[Pressman, Jonathan. G.]的文章
百度学术
百度学术中相似的文章
[Lee, Woo Hyoung]的文章
[Wahman, David. G.]的文章
[Pressman, Jonathan. G.]的文章
必应学术
必应学术中相似的文章
[Lee, Woo Hyoung]的文章
[Wahman, David. G.]的文章
[Pressman, Jonathan. G.]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。