CCPortal
DOI10.1021/acs.est.6b01105
Performance of Passive Samplers Analyzed by Computer -Controlled Scanning Electron Microscopy to Measure PM10-2.5
Peters, Thomas M.1; Sawvel, Eric J.1; Willis, Robert2; West, Roger R.3; Casuccio, Gary S.3
发表日期2016-07-19
ISSN0013-936X
卷号50期号:14页码:7581-7589
英文摘要

We report on the precision and accuracy of measuring PM10-2.5 and its components with particles collected by passive, aerosol samplers and analyzed by computer controlled scanning electron microscopy with energy dispersive X-ray spectroscopy. Passive samplers were deployed for week-long intervals in triplicate and colocated with a federal reference method sampler at three sites and for 5 weeks in summer 2009 and 5 weeks in winter 2010 in Cleveland, OH. The limit of detection of the passive method for PM10-2.5 determined from blank analysis was 2.8 mu g m(-3). Overall precision expressed as root-mean-square coefficient of variation (CVRMS) improved with increasing concentrations (37% for all samples, n = 30; 19% for PM10-2.5 > 10 mu g m(-3)) n = 9; and 10% for PM10-2.5 > 15 mu g m(-3), n = 4). The linear regression of PM10-2.5 measured passively on that measured with the reference sampler exhibited an intercept not statistically different than zero (p = 0.46) and a slope not statistically different from unity (p = 0.92). Triplicates with high CVs (CV > 40%, n = 5) were attributed to low particle counts (and mass concentrations), spurious counts attributed to salt particles, and Al-rich particles. This work provides important quantitative observations that can help guide future development and use of passive samplers for measuring atmospheric particulate matter.


语种英语
WOS记录号WOS:000380295700035
来源期刊ENVIRONMENTAL SCIENCE & TECHNOLOGY
来源机构美国环保署
文献类型期刊论文
条目标识符http://gcip.llas.ac.cn/handle/2XKMVOVA/58431
作者单位1.Univ Iowa, Iowa City, IA 52242 USA;
2.US EPA, Off Res & Dev, Natl Exposure Res Lab, Res Triangle Pk, NC 27709 USA;
3.RJ Lee Grp Inc, Monroeville, PA 15146 USA
推荐引用方式
GB/T 7714
Peters, Thomas M.,Sawvel, Eric J.,Willis, Robert,et al. Performance of Passive Samplers Analyzed by Computer -Controlled Scanning Electron Microscopy to Measure PM10-2.5[J]. 美国环保署,2016,50(14):7581-7589.
APA Peters, Thomas M.,Sawvel, Eric J.,Willis, Robert,West, Roger R.,&Casuccio, Gary S..(2016).Performance of Passive Samplers Analyzed by Computer -Controlled Scanning Electron Microscopy to Measure PM10-2.5.ENVIRONMENTAL SCIENCE & TECHNOLOGY,50(14),7581-7589.
MLA Peters, Thomas M.,et al."Performance of Passive Samplers Analyzed by Computer -Controlled Scanning Electron Microscopy to Measure PM10-2.5".ENVIRONMENTAL SCIENCE & TECHNOLOGY 50.14(2016):7581-7589.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Peters, Thomas M.]的文章
[Sawvel, Eric J.]的文章
[Willis, Robert]的文章
百度学术
百度学术中相似的文章
[Peters, Thomas M.]的文章
[Sawvel, Eric J.]的文章
[Willis, Robert]的文章
必应学术
必应学术中相似的文章
[Peters, Thomas M.]的文章
[Sawvel, Eric J.]的文章
[Willis, Robert]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。