Climate Change Data Portal
DOI | 10.1002/jgrd.50215 |
A high-frequency response relaxed eddy accumulation flux measurement system for sampling short-lived biogenic volatile organic compounds | |
Arnts, Robert R.1; Mowry, Fred L.2,3; Hampton, Gary A.4 | |
发表日期 | 2013-05-27 |
ISSN | 2169-897X |
卷号 | 118期号:10页码:4860-4873 |
英文摘要 | A second-generation relaxed eddy accumulation system was built and tested with the capability to measure vertical biogenic volatile organic compound (VOC) fluxes at levels as low as 10 mu gCm(-2)hr(-1). The system features a continuous, integrated gas-phase ozone removal procedure to allow for the measurement of highly reactive species such as -caryophyllene and polar terpenoids such as linalool. A two-component internal standard continuously added to the accumulators was used to correct for switching-induced volumetric errors and as a check on VOC losses exceeding accumulator tube adsorption limits. In addition, the internal standards were used to demonstrate that accumulators quickly return to target flow rates at segregation valve switching frequencies up to at least 0.8Hz. The system was able to measure daytime hourly fluxes of individual biogenic VOC including oxygenated terpenoids, monoterpenes, and sesquiterpenes. |
英文关键词 | flux measurement;REA;biogenic VOC |
语种 | 英语 |
WOS记录号 | WOS:000325272000067 |
来源期刊 | JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES
![]() |
来源机构 | 美国环保署 |
文献类型 | 期刊论文 |
条目标识符 | http://gcip.llas.ac.cn/handle/2XKMVOVA/58208 |
作者单位 | 1.US EPA, Natl Exposure Res Lab, Human Exposure & Atmospher Sci Div, Res Triangle Pk, NC 27711 USA; 2.Duke Univ, Nicholas Sch Environm & Earth Sci, Durham, NC USA; 3.US EPA, Natl Risk Management Res Lab, Air Pollut Prevent Control Div, Res Triangle Pk, NC 27711 USA; 4.Hampton Technol Inc, Longmont, CO USA |
推荐引用方式 GB/T 7714 | Arnts, Robert R.,Mowry, Fred L.,Hampton, Gary A.. A high-frequency response relaxed eddy accumulation flux measurement system for sampling short-lived biogenic volatile organic compounds[J]. 美国环保署,2013,118(10):4860-4873. |
APA | Arnts, Robert R.,Mowry, Fred L.,&Hampton, Gary A..(2013).A high-frequency response relaxed eddy accumulation flux measurement system for sampling short-lived biogenic volatile organic compounds.JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES,118(10),4860-4873. |
MLA | Arnts, Robert R.,et al."A high-frequency response relaxed eddy accumulation flux measurement system for sampling short-lived biogenic volatile organic compounds".JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES 118.10(2013):4860-4873. |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。