CCPortal
DOI10.1002/jgrd.50215
A high-frequency response relaxed eddy accumulation flux measurement system for sampling short-lived biogenic volatile organic compounds
Arnts, Robert R.1; Mowry, Fred L.2,3; Hampton, Gary A.4
发表日期2013-05-27
ISSN2169-897X
卷号118期号:10页码:4860-4873
英文摘要

A second-generation relaxed eddy accumulation system was built and tested with the capability to measure vertical biogenic volatile organic compound (VOC) fluxes at levels as low as 10 mu gCm(-2)hr(-1). The system features a continuous, integrated gas-phase ozone removal procedure to allow for the measurement of highly reactive species such as -caryophyllene and polar terpenoids such as linalool. A two-component internal standard continuously added to the accumulators was used to correct for switching-induced volumetric errors and as a check on VOC losses exceeding accumulator tube adsorption limits. In addition, the internal standards were used to demonstrate that accumulators quickly return to target flow rates at segregation valve switching frequencies up to at least 0.8Hz. The system was able to measure daytime hourly fluxes of individual biogenic VOC including oxygenated terpenoids, monoterpenes, and sesquiterpenes.


英文关键词flux measurement;REA;biogenic VOC
语种英语
WOS记录号WOS:000325272000067
来源期刊JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES
来源机构美国环保署
文献类型期刊论文
条目标识符http://gcip.llas.ac.cn/handle/2XKMVOVA/58208
作者单位1.US EPA, Natl Exposure Res Lab, Human Exposure & Atmospher Sci Div, Res Triangle Pk, NC 27711 USA;
2.Duke Univ, Nicholas Sch Environm & Earth Sci, Durham, NC USA;
3.US EPA, Natl Risk Management Res Lab, Air Pollut Prevent Control Div, Res Triangle Pk, NC 27711 USA;
4.Hampton Technol Inc, Longmont, CO USA
推荐引用方式
GB/T 7714
Arnts, Robert R.,Mowry, Fred L.,Hampton, Gary A.. A high-frequency response relaxed eddy accumulation flux measurement system for sampling short-lived biogenic volatile organic compounds[J]. 美国环保署,2013,118(10):4860-4873.
APA Arnts, Robert R.,Mowry, Fred L.,&Hampton, Gary A..(2013).A high-frequency response relaxed eddy accumulation flux measurement system for sampling short-lived biogenic volatile organic compounds.JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES,118(10),4860-4873.
MLA Arnts, Robert R.,et al."A high-frequency response relaxed eddy accumulation flux measurement system for sampling short-lived biogenic volatile organic compounds".JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES 118.10(2013):4860-4873.
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Arnts, Robert R.]的文章
[Mowry, Fred L.]的文章
[Hampton, Gary A.]的文章
百度学术
百度学术中相似的文章
[Arnts, Robert R.]的文章
[Mowry, Fred L.]的文章
[Hampton, Gary A.]的文章
必应学术
必应学术中相似的文章
[Arnts, Robert R.]的文章
[Mowry, Fred L.]的文章
[Hampton, Gary A.]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。