Climate Change Data Portal
DOI | 10.1016/j.enpol.2022.113156 |
Heat pump inspections result in large energy savings when a pre-selection of households is performed: A promising use case of smart meter data | |
Weigert, Andreas; Hopf, Konstantin; Guenther, Sebastian A.; Staake, Thorsten | |
发表日期 | 2022 |
ISSN | 0301-4215 |
EISSN | 1873-6777 |
卷号 | 169页码:15 |
英文摘要 | Heat pumps play an important role in the energy transition. They can extract renewable energy from the air or ground and increasingly replace fossil heating systems in buildings. In operation, however, heat pumps often consume more electricity than necessary due to incorrect settings and installation deficiencies. Although many setting and installation issues are easy to fix, problems often go unnoticed, and the saving potential from quick fixes remains unclear. In a study with 297 Swiss households (41 treatment, 256 control) running for four years, we investigated an energy efficiency campaign in which the treatment group received a professional heat pump inspection and user training. We found considerable heterogeneity with respect to the savings achieved. We derived two criteria based on smart meter data that enable utilities to identify relevant households and thus boost the impact of such efficiency campaigns: For example, pre-selecting half of the households based on available information results in average savings of 1,805 kWh (15.2%) per year and household in the high-potential group compared to no savings in the low-potential group. Thus, heat pump inspections among pre-selected households can lead to large, cost-effective electricity savings, and we show that common smart meter data makes such pre-selection feasible. |
英文关键词 | Heat pump; Energy consulting; Energy efficiency; Smart meter data; Data analytics |
学科领域 | Economics; Energy & Fuels; Environmental Sciences; Environmental Studies |
语种 | 英语 |
WOS研究方向 | Business & Economics ; Energy & Fuels ; Environmental Sciences & Ecology |
WOS记录号 | WOS:000848156600001 |
来源期刊 | ENERGY POLICY |
文献类型 | 期刊论文 |
条目标识符 | http://gcip.llas.ac.cn/handle/2XKMVOVA/272325 |
作者单位 | Otto Friedrich University Bamberg; Swiss Federal Institutes of Technology Domain; ETH Zurich |
推荐引用方式 GB/T 7714 | Weigert, Andreas,Hopf, Konstantin,Guenther, Sebastian A.,et al. Heat pump inspections result in large energy savings when a pre-selection of households is performed: A promising use case of smart meter data[J],2022,169:15. |
APA | Weigert, Andreas,Hopf, Konstantin,Guenther, Sebastian A.,&Staake, Thorsten.(2022).Heat pump inspections result in large energy savings when a pre-selection of households is performed: A promising use case of smart meter data.ENERGY POLICY,169,15. |
MLA | Weigert, Andreas,et al."Heat pump inspections result in large energy savings when a pre-selection of households is performed: A promising use case of smart meter data".ENERGY POLICY 169(2022):15. |