Climate Change Data Portal
DOI | 10.1016/j.rse.2021.112413 |
Instrumentation sensitivities for tower-based solar-induced fluorescence measurements | |
Marrs J.K.; Jones T.S.; Allen D.W.; Hutyra L.R. | |
发表日期 | 2021 |
ISSN | 00344257 |
卷号 | 259 |
英文摘要 | Solar-induced chlorophyll fluorescence (SIF) has been widely cited as a proxy for photosynthesis and is being incorporated as a common input in terrestrial primary productivity models. Though satellite-based SIF products show close relationships with terrestrial gross primary productivity (GPP), there is wide variability in the magnitude of published SIF retrievals made at intermediate scales. In a meta-analysis of the tower-based and airborne SIF literature, we found that mean SIF retrievals from unstressed vegetation spanned a wide range, from 0.041 mW m−2 nm−1 sr−1 to 14.8 mW m−2 nm−1 sr−1, with a majority of values falling below 4 mW m−2 nm−1 sr−1. We compiled information on reported spectrometer calibration procedures, hardware characterizations, and associated corrections from these same papers, and found inconsistent reporting on if and how key calibration methodology was performed. In order to quantify the importance of such methodological differences on final SIF retrievals made at a proximal scale, we performed radiometric calibrations and corrections for electronic dark current, detector noise, atmospheric O2 absorbance, and cosine corrector effects on three field-deployed spectrometers. We found dramatic changes in SIF retrieval magnitude before and after applying calibrations and corrections, as well as significant differences between instrument performance in the field and expected performance based on laboratory characterizations. Based on these tests, and on a Monte Carlo simulation of uncertainty estimates associated with each of these corrections, it is likely that calibration methodologies and hardware characterizations explain some of the observed variability in published SIF retrievals. This wide range in baseline SIF retrieval methodologies and resultant magnitudes severely limit researchers' ability to synthesize and advance the utility of SIF in modeling GPP across scales. Further, variability in calibration and correction methodology may explain the weak SIF-GPP relationship across studies at tower scales. © 2021 Elsevier Inc. |
英文关键词 | Atmospheric correction; Instrument characterization; Solar-induced fluorescence; Tower-based remote sensing |
语种 | 英语 |
scopus关键词 | Calibration; Chlorophyll; Fluorescence; Intelligent systems; Monte Carlo methods; Photosynthesis; Phytoplankton; Spectrometers; Towers; Uncertainty analysis; Atmospheric corrections; Calibration methodologies; Chlorophyll fluorescence; Fluorescence measurements; Gross primary productivity; Hardware characterization; Instrument characterization; Primary productivity; Solar-induced fluorescences; Tower-based remote sensing; Remote sensing |
来源期刊 | Remote Sensing of Environment
![]() |
文献类型 | 期刊论文 |
条目标识符 | http://gcip.llas.ac.cn/handle/2XKMVOVA/178856 |
作者单位 | Department of Earth & Environment, Boston University, 675 Commonwealth Avenue, Rm. 130, Boston, MA 02215, United States; Remote Sensing Group, National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, MD 20899, United States |
推荐引用方式 GB/T 7714 | Marrs J.K.,Jones T.S.,Allen D.W.,et al. Instrumentation sensitivities for tower-based solar-induced fluorescence measurements[J],2021,259. |
APA | Marrs J.K.,Jones T.S.,Allen D.W.,&Hutyra L.R..(2021).Instrumentation sensitivities for tower-based solar-induced fluorescence measurements.Remote Sensing of Environment,259. |
MLA | Marrs J.K.,et al."Instrumentation sensitivities for tower-based solar-induced fluorescence measurements".Remote Sensing of Environment 259(2021). |
条目包含的文件 | 条目无相关文件。 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。