Consideration of peak cut method by air conditioning equipment corresponding to demand for contract power reduction—Application of thermal radiative cooling/heating system | |
Satake A.; Jike J.; Mitani Y. | |
发表日期 | 2020 |
ISSN | 23524847 |
起始页码 | 768 |
结束页码 | 774 |
卷号 | 6 |
英文摘要 | Electricity demand leveling has actively been pursued in order to reduce power supply costs and reduce carbon dioxide emissions. In addition, large-scale customers have attracted great interest because of the expectation of contract power reduction. Focusing on the air conditioning equipment whose seasonal factors greatly change their demand, the peak cut operation has been considered for customers who have a large proportion of the load on the air conditioning equipment. The thermal radiative cooling/heating system is applied as the air conditioning equipment, and power control is performed according to the electricity demand of the customer. The comfort is evaluated by simulating the change in room temperature at that time. As a result, it is shown that the proposed demand response method can perform peak cut operation while ensuring comfort. © 2020 The Authors |
英文关键词 | Air conditioning equipment; Contract power reduction; Demand response; Peak cut; Thermal radiative cooling/heating system |
scopus关键词 | Air conditioning; Carbon dioxide; Electric power utilization; Global warming; Power control; Radiative Cooling; Sales; Carbon dioxide emissions; Conditioning equipment; Demand response; Electricity demands; Power reductions; Power supply; Seasonal factors; Electric power system control |
来源期刊 | Energy Reports |
文献类型 | 期刊论文 |
条目标识符 | http://gcip.llas.ac.cn/handle/2XKMVOVA/176727 |
作者单位 | Kyushu Institute of Technology, 1-1 Sensui-cho, Tobata-ku, Kitakyushu, Fukuoka 804-8550, Japan |
推荐引用方式 GB/T 7714 | Satake A.,Jike J.,Mitani Y.. Consideration of peak cut method by air conditioning equipment corresponding to demand for contract power reduction—Application of thermal radiative cooling/heating system[J],2020,6. |
APA | Satake A.,Jike J.,&Mitani Y..(2020).Consideration of peak cut method by air conditioning equipment corresponding to demand for contract power reduction—Application of thermal radiative cooling/heating system.Energy Reports,6. |
MLA | Satake A.,et al."Consideration of peak cut method by air conditioning equipment corresponding to demand for contract power reduction—Application of thermal radiative cooling/heating system".Energy Reports 6(2020). |
条目包含的文件 | 条目无相关文件。 |