CCPortal
DOI10.1029/2019GL086791
A Post-2013 Dropoff in Total Ozone at a Third of Global Ozonesonde Stations: Electrochemical Concentration Cell Instrument Artifacts?
Stauffer R.M.; Thompson A.M.; Kollonige D.E.; Witte J.C.; Tarasick D.W.; Davies J.; Vömel H.; Morris G.A.; Van Malderen R.; Johnson B.J.; Querel R.R.; Selkirk H.B.; Stübi R.; Smit H.G.J.
发表日期2020
ISSN 0094-8276
卷号47期号:11
英文摘要An international effort to improve ozonesonde data quality and to reevaluate historical records has made significant improvements in the accuracy of global network data. However, between 2014 and 2016, ozonesonde total column ozone (TCO; O3) at 14 of 37 regularly reporting stations exhibited a sudden dropoff relative to satellite measurements. The ozonesonde TCO drop is 3–7% compared to satellite and ground-based TCO, and 5–10% or more compared to satellite stratospheric O3 profiles, compromising the use of recent data for trends, although they remain reliable for other uses. Hardware changes in the ozonesonde instrument are likely a major factor in the O3 dropoff, but no single property of the ozonesonde explains the findings. The bias remains in recent data. Research to understand the dropoff is in progress; this letter is intended as a caution to users of the data. Our findings underscore the importance of regular ozonesonde data evaluation. ©2020. American Geophysical Union. All Rights Reserved.
英文关键词Ozone; Satellites; Data evaluation; Electrochemical concentration; Global networks; Ground based; Historical records; Major factors; Satellite measurements; Total column ozone; Meteorological instruments; artifact; concentration (composition); data quality; electrochemistry; instrumentation; ozone; ozonesonde; satellite data; stratosphere
语种英语
来源期刊Geophysical Research Letters
文献类型期刊论文
条目标识符http://gcip.llas.ac.cn/handle/2XKMVOVA/170278
作者单位Earth System Science Interdisciplinary Center, University of Maryland, College Park, MD, United States; Atmospheric Chemistry and Dynamics Lab, NASA/GSFC, Greenbelt, MD, United States; Science Systems and Applications, Inc., Lanham, MD, United States; Now at National Center for Atmospheric Research Earth Observations Laboratory, Boulder, CO, United States; Environment and Climate Change Canada, Downsview, ON, Canada; National Center for Atmospheric Research Earth Observations Laboratory, Boulder, CO, United States; St. Edward's University, Austin, TX, United States; Royal Meteorological Institute of Belgium, Uccle, Belgium; Global Monitoring Laboratory, NOAA Earth System Research Laboratory, Boulder, CO, United States; National Institute of Water and Atmospheric Research (NIWA), Lauder, New Zealand; Universities Space Research Association, Columbia, MD, United States; Federal Office of Meteorology and Climatology, MeteoSwiss, Aerological Station, Payerne, Switzerland; Institute of Chemistry and Dynamics o...
推荐引用方式
GB/T 7714
Stauffer R.M.,Thompson A.M.,Kollonige D.E.,et al. A Post-2013 Dropoff in Total Ozone at a Third of Global Ozonesonde Stations: Electrochemical Concentration Cell Instrument Artifacts?[J],2020,47(11).
APA Stauffer R.M..,Thompson A.M..,Kollonige D.E..,Witte J.C..,Tarasick D.W..,...&Smit H.G.J..(2020).A Post-2013 Dropoff in Total Ozone at a Third of Global Ozonesonde Stations: Electrochemical Concentration Cell Instrument Artifacts?.Geophysical Research Letters,47(11).
MLA Stauffer R.M.,et al."A Post-2013 Dropoff in Total Ozone at a Third of Global Ozonesonde Stations: Electrochemical Concentration Cell Instrument Artifacts?".Geophysical Research Letters 47.11(2020).
条目包含的文件
条目无相关文件。
个性服务
推荐该条目
保存到收藏夹
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Stauffer R.M.]的文章
[Thompson A.M.]的文章
[Kollonige D.E.]的文章
百度学术
百度学术中相似的文章
[Stauffer R.M.]的文章
[Thompson A.M.]的文章
[Kollonige D.E.]的文章
必应学术
必应学术中相似的文章
[Stauffer R.M.]的文章
[Thompson A.M.]的文章
[Kollonige D.E.]的文章
相关权益政策
暂无数据
收藏/分享

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。