Climate Change Data Portal
DOI | 10.2478/rtuect-2019-0009 |
In-situ moisture assessment in external walls of historic building using non-destructive methods | |
Freimanis R.; Vaiskunaite R.; Bezrucko T.; Blumberga A. | |
发表日期 | 2019 |
ISSN | 22558837 |
起始页码 | 122 |
结束页码 | 134 |
卷号 | 23期号:1 |
英文摘要 | In-situ measurements of a case study building located in Riga old town near the river Daugava has been carried out in this work. Performed measurements are moisture level of historic masonry, and interstitial monitoring of temperature and relative humidity between the layers of internal insulation and external wall. Obtained results are compared with outdoor weather data. Results show that during the cold months of the year no rising damp problem. No interstitial condensation under the internal insulation, and no risk of mold growth occur. However, the façade of the building tends to be highly influenced by the outdoor weather, and the moisture of the masonry increases during the rain load events. © 2019 Ritvars Freimanis et al., published by Sciendo 2019. |
关键词 | dielectric propertyhistoric buildingin situ measurementinsulationmasonrynondestructive testingrelative humiditywallDaugava RiverLatviaRiga |
语种 | 英语 |
来源机构 | Environmental and Climate Technologies |
文献类型 | 期刊论文 |
条目标识符 | http://gcip.llas.ac.cn/handle/2XKMVOVA/132576 |
推荐引用方式 GB/T 7714 | Freimanis R.,Vaiskunaite R.,Bezrucko T.,et al. In-situ moisture assessment in external walls of historic building using non-destructive methods[J]. Environmental and Climate Technologies,2019,23(1). |
APA | Freimanis R.,Vaiskunaite R.,Bezrucko T.,&Blumberga A..(2019).In-situ moisture assessment in external walls of historic building using non-destructive methods.,23(1). |
MLA | Freimanis R.,et al."In-situ moisture assessment in external walls of historic building using non-destructive methods".23.1(2019). |